Device and Functional Specifications
MicroPeckerX Hardware
| Item | Specification |
|---|---|
| Power | USB bus power (5 V, 300 mA) |
| Dimensions | 65 (W) × 35 (D) × 16 (H) mm |
| Weight | 45 g |
| LED indicators | 4 LEDs Orange: Power (on when powered) Green: Comm CH1 (blinks during LIN) Yellow: Comm CH2 (blinks during DIO/AD) Red: Error (on when faults occur) |
| Sync interface | 2 ports |
| DIO/AD interface | 9-pin DIO connector, 1 channel (monitor up to 4 DIO points + 1 AD point) |
| DIO port voltage | Input: 3.3–5 V / Output: 3.3 V |
| AD range | 0–5.5 V / 16.5 V / 45 V |
| Protection | Built-in ESD, reverse polarity, overcurrent protection |
| USB ports | Two USB Micro-B (main and sub) |
Compliance
- CE
EMI: EN55011(2020) Group 1 Class B
EMS: EN61000-4-2(2009), EN61000-4-3(2010) - FCC
Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Front View
Top/Bottom
Left/Right
Do not use the secondary USB port.
LIN 1ch Clip Cable
| Item | Specification |
|---|---|
| Signals | LIN, VBAT, GND (clip connector) |
| Cable length | 0.3 m |
| Shield | None |
Connector
Sync Cable
| Item | Specification |
|---|---|
| Cable length | 25 cm |
| Shield | None |
The sync cable is not used in this system.
MicroPeckerX DIO/AD License Features
| Item | Details | |
|---|---|---|
| DIO | Channels | 4 (individually configurable) |
| Direction | Switch Input / Output per channel | |
| Input pull | Select Pull-Up / Pull-Down / None | |
| Output level | Choose Hi / Lo | |
| Output mode | Open-Drain / Push-Pull | |
| Voltage | 0–3.3 V | |
| Monitoring period | 1–60,000 ms | |
| Label filter | Lo, Hi, Lo→Hi, Hi→Lo, wildcard | |
| Log output | File and screen (up to 100,000 records) | |
| Log format | CSV, AD data (physical values planned) | |
| Log splitting | None / File size 1–4095 MB / Records 100–2,500,000 / Timer 1–3600 sec | |
| Trigger modes | Free Run, Start Trigger, Stop Trigger | |
| Trigger sources | Specific data, key input | |
| AD | Sampling frequency | 1 Hz–10 kHz (1 Hz steps) |
| Sampling period | 0.1–1000 ms | |
| Channels | 1 | |
| Input range | 0 V to 5 V / 15 V / 40 V | |
| Resolution | 12 bit | |
| Accuracy (DC) | ±17.5 mV | |
| Noise tolerance | No filter | |
| Monitor data format | AD conversion data (physical values planned) | |
| Log output | File and screen (up to 100,000 records) | |
| Log format | CSV, hexadecimal | |
| Log splitting | None / File size 1–4095 MB / Records 100–2,500,000 / Timer 1–3600 sec | |