Skip to main content
Version: Ver.4.10

Managing Signal Catalog and Communication Definitions

Overview​

Signal Catalog manages signal definitions and Signal Sets. Open it using “Signal Catalog” on the main toolbar. The button with the same name in Signal Window provides an alternative entry point. Definitions are shared across Sets, while channels and display settings are managed per Set.

Roles and Terminology​

TermMeaning
Frame / MessageA communication unit with an ID, data length, and data. Multiple signals can be defined in one frame.
Bus signalA signal obtained by extracting bits from frame data. Shown as Bus signal in the Catalog.
Derived signalA signal calculated using registered signals as inputs.
Raw valueThe unconverted value extracted from a frame. Distinguish this from the HEX display of all data bytes.
Physical valueA numeric value converted from a Raw value using a factor, offset, or similar conversion; for example, speed in km/h.
Logical valueA state name corresponding to a Raw value; for example, displaying 0 as Off and 1 as On.
Signal CatalogThe screen for managing signal and frame definitions.
Signal SetA combination of signals selected from the Catalog, with channel and display destination settings.
Current SetThe Signal Set currently in use. Check that it matches the Set you are editing in the Catalog.

Monitoring a signal registered in the Catalog requires Set membership (In Set), a channel assignment, and an enabled display destination. To use the Set selected for editing, switch to it with “Set Current.”

The arrows represent selection/application operations, not continuous synchronization with every destination. Analysis also uses recorded definitions and MPXSIG files. See Selecting Analysis Definitions.

Screen Reference​

The examples below show FanDemo. These definitions differ from SensorFrame in the included sample. The shared screen also shows LIN definitions and tabs. FD2 uses Signals and Frames for CAN/CAN FD.

Signals tab example

Signal Catalog Signals tab, with Signal Sets on the left and In Set, signal names, channels, and selected signal details on the right

Frames tab example

Signal Catalog Frames tab listing frame IDs, data lengths, import sources, and availability for transmission settings
ItemDescription
SearchSearches the list by name and other properties. Clear the search text if you cannot find an item.
Catalog countShows the total number of registered Catalog entries and the limit.
SignalsShows signal definitions and their membership/usage in the selected Set.
FramesShows frame definitions. Check which frames can be used to generate simulation settings.
LIN SchedulesShows LIN schedules imported from an LDF.
Signal SetsSelects the Set to edit. The Set marked Current is currently in use.
Only selected SetShows only signals belonging to the selected Set.
In SetAdds a signal to the selected Set. Turning it off leaves the definition in the Catalog.
Signal DetailsShows the definition and settings for the selected Set. Expand or collapse using the heading.
MemoEdits a memo for the selected definition.
Close buttonCloses the Catalog. Individually confirmed operations are retained.

Signals Tab Operations​

ButtonOperation
+ Signal buttonAdds a bus signal.
+ Derived buttonAdds a derived signal.
Edit buttonEdits the selected definition and settings such as its display settings in the selected Set.
Copy buttonDuplicates the selected definition. This differs from duplicating an entire Set.
Delete buttonDeletes the selected definition from the Catalog. To remove only its membership, turn off In Set instead.
Import buttonImports communication definition files such as DBC files.
Remove ImportDeletes all definitions from the selected import source file.
Save buttonSaves the Catalog and all Signal Sets to MPXSIG.
Load buttonLoads the Catalog and all Signal Sets from an MPXSIG file.
Editing Shared Definitions

Editing or deleting a definition also affects other Sets that use it. Check its uses before changing frame conditions or bit positions. If derived signals, triggers, or other settings reference it, resolve the references according to the confirmation or error messages on the screen.

Signal Sets Operations​

Button / itemDescription
Add Set buttonCreates an empty Set.
Duplicate Set buttonDuplicates the selected Set. Distinguish this from Copy for duplicating definitions.
Rename buttonRenames the selected Set.
Delete Set buttonDeletes the selected Set. This does not delete signal definitions from the Catalog.
Set Current buttonMakes the selected Set active. Check the display targets in Signal Window.
Signals countShows the signal count and limit for the selected Set. Account for input signals required by derived signals.

Adding Signals to a Set​

This example assigns a destination channel. Select CH1-1 in the Assign Channel - WebManual list and confirm with OK. The title shows the name of the Set being modified.

Dialog selecting CH1-1 as the destination for signals added to the WebManual Set
  1. Select the Set to edit under Signal Sets.
  2. Turn off Only selected Set if necessary and find the target in the Signals list.
  3. Turn on In Set, select the channel in Assign Channel, and click OK.
  4. Check the channel and display targets using Edit.
  5. Click Set Current, then Close. Check that the target appears in Current Set.

Signals registered only in the Catalog, or signals whose saved destination device is unavailable, may be retained without a channel assignment. A definition in the list is not associated with actual frames until a channel is assigned.

Deleting Definitions and Effects on Their Uses​

To check an import source, click Remove Import to the right of Import in Signal Catalog. Imported Files opens first. No definitions are deleted at this stage.

Import and Remove Import on the Signal Catalog toolbar
OperationWhat changesRetained settings / uses to check
Turn off In SetRemoves the signal from the selected Set.The Catalog definition and other Sets remain. Also check inputs required by derived signals.
Delete in SignalsDeletes the selected definition from the Catalog.Check Sets sharing it and settings referencing the signal being deleted.
Delete a SetDeletes the selected Set and its channel assignments/display settings.Catalog definitions remain. If Current Set changes, check affected uses.
Remove ImportDeletes imported definitions from the selected file together.Affects definition references in Sets, derived signals, Trigger, and transmission settings. Transmission slots and configured HEX data remain.
Load MPXSIGReplaces the shared Catalog and all Sets with the file contents.Check channels, display destinations, and Trigger references. Recreating HEX data in existing transmission slots is a separate operation.

For Remove Import, select the target file in Imported files. Click “Remove Import,” then check the definitions to delete and effects on Trigger/transmission settings under “Details” in the confirmation screen before confirming. “Cancel” during impact review cancels deletion. Closing the Catalog after confirmation does not undo changes. Before deleting or replacing definitions, you can save the current Catalog to MPXSIG.

Definition / usage operationMonitoring / TriggerExisting analysis resultsExisting transmission settings
Edit a shared definitionApplied to Sets sharing the definition. Check selected Trigger conditions.Apply the definitions and rerun analysis to use them.Previously applied values are retained. Apply again to use the changes.
Change In SetChanges signals used in the selected Set. Check selected Trigger definitions/channels separately.Apply the analysis Set and rerun analysis.Monitoring Set membership alone does not change slots.
Switch Current SetSwitches monitoring targets. Recheck uses of selected Triggers.Apply on the analysis side to use current definitions.Slot settings are retained.
Change analysis definitionsDoes not change shared definitions. Check Trigger targets and enabled state before resuming monitoring.Retains previous results; rerun analysis with the new conditions.Slot settings are retained.
Apply to transmissionMonitoring Set and Trigger settings are separate.Analysis settings are separate.Adds or replaces selected slots.
Remove an import sourceResolves dependencies and deletes affected Triggers.Saved logs and definition files remain.Removes affected definition references. Frames and HEX data are retained.
Load MPXSIGReplaces all Sets. Check channels and Triggers.Loading the shared Catalog is separate from loading analysis definitions.Frames and HEX data are updated when applied.

Saving and Loading​

Saving​

  1. Confirm each editing dialog with OK.
  2. Click Save in the Catalog.
  3. Specify the destination and file name, and save with the MPXSIG extension.

MPXSIG saves the Catalog and all Signal Sets together. Its purpose differs from the original DBC, communication logs, analysis result CSV files, and regular configuration files. Also manage the original communication definition files so that the version used can be identified.

Loading​

  1. To retain the current Catalog, first Save it under a different name.
  2. Select an MPXSIG file using Load.
  3. Read the “Replace the Catalog and all Signal Sets?” confirmation and proceed if you want to replace them.
  4. Check Set names, signal counts, Current Set, channels, conversion formulas, and display destinations.
Loading Replaces the Catalog and All Sets

Load does not simply add the selected Set. If any part of the connected device/channel configuration differs from when the file was saved, channel assignments are cleared in all Sets. Check the definitions and display settings, and reassign channels for the signals you use. Closing with Close does not undo a confirmed load operation.

Restoring Saved Sets at Startup or Device Refresh​

At startup, the application restores the Current Set automatically saved at the previous shutdown. “Device” → “Refresh” rechecks the destinations of assignments in the current Set. To use an MPXSIG saved under a different name, use Load as described above. Saved Set channel assignments are retained, and signals on connected channels whose device serial number, internal channel, and device type match are included in monitoring. If the same physical channel is recognized under a different channel number, the channel number used during monitoring is mapped automatically.

Signals whose destination channels cannot be verified, and derived signals that depend on unavailable inputs, remain pending. Reconnect the saved device and run “Refresh” to recheck assignments. Status bar messages show pending assignments or channel-number differences. When loading signal settings from MPXXML, also check the loading restrictions.

Registration Limits​

ItemLimit
Catalog10,000 entries
Signal Set10 Sets
One Set128 signals, including required input signals
Graph targets32 signals

Distinguish the Catalog count from the number used in Current Set. The 128-signal limit is the total across all channels, including required input signals, not a per-channel limit. If a limit is reached, separate Sets by purpose and organize the signals in use.

For saved-log analysis, result output, and use in transmission settings, see the respective instructions.