Troubleshooting

ProblemActionNote
MicroPeckerX is not detected by the configuration software.Please check the following:
- Is the USB driver installed?
- Are the PC and MicroPeckerX connected correctly?
- If you use a USB hub, is it self-powered?
-
An error occurs when loading the GW setting file.Check the following based on the error message:
- Device Error: Is MicroPeckerX connected correctly?
- File not found.: Did you select a non-existent file?
- File Format Error: Were sheets deleted or renamed?
- Import Error: Are values in the displayed sheet name and cell positions correct?
- Unknown Error: Is the selected file open in Excel or another app?
The sheet order must be Com, Immediate GW, Gateway, Periodic Frame (additional sheets may be added after these).
An error occurs when reading GW settings.Check the following based on the error message:
- Device Error: Is MicroPeckerX connected correctly?
- Unknown Error: Is the saved file open in Excel or another app?
-
No transmission or gateway operation occurs from MicroPeckerX.Power-cycle MicroPeckerX.GW settings written from the configuration software to the MicroPeckerX unit do not take effect until the unit is power-cycled.