Device Connection Method

Connecting and Disconnecting Devices​

This chapter explains the procedures for connecting and disconnecting devices.

How to Connect Devices​

Connect MicroPeckerX to a Windows PC​

Use the included USB cable to connect MicroPeckerX to a USB port on the PC.

PC and MPX connection

Note: Only the left USB port is available. Do not remove the cap on the right side.

Connect to the Target​

Use a CAN cable to connect MicroPeckerX to the CAN / CAN FD bus. Connections to CAN Hi, CAN Lo, and GND are required.

When using GW function

Connect Synchronization Cable​

When synchronizing multiple MicroPeckerX units, connect them with the synchronization cable included with this product.

CAN 2ch Dsub cable
Connection Example for 3 Units​
Connection example for 3 units

Note: Connect/disconnect synchronization cables only while monitoring is stopped.

Switching Termination Resistor​

ON/OFF switching of the termination resistor can be configured in the GUI application.

How to Disconnect Devices​

The procedure for disconnecting devices is described below.

Disconnect MicroPeckerX from Windows PC​

Unplug MicroPeckerX from the Windows PC.

MPX disconnect

D-sub Connector Details​

D-sub pin assignments are as follows.

MicroPeckerX Main Unit S810-MX-FD2​

Main unit D-sub connector
PinFunction
1CAN Lo(CH1)
2CAN Lo(CH0)
3GND
4Not Connected.
5Not Connected.
6GND
7CAN Hi(CH0)
8CAN Hi(CH1)
9Not Connected.

CAN 1ch Clip Cable S810-MX-CB1​

CAN 1ch Clip Cable
PinFunction
1Not Connected.
2CAN Lo
3GND
4Not Connected.
5Not Connected.
6Not Connected.
7CAN Hi
8Not Connected.
9Not Connected.

CAN 2ch D-sub Cable S810-MX-CB2 (Ch1/Ch2 connector side)​

CAN 2ch D-sub Cable
PinFunction
1Not Connected.
2CAN Lo
3GND
4Not Connected.
5Not Connected.
6Not Connected.
7CAN Hi
8Not Connected.
9Not Connected.

Note: The 2-channel connector is split into individual 1-channel lines.

Caution

Incorrect wiring may damage both MicroPeckerX and the target device.