Restrictions
This page describes restrictions when developing applications with this product and when using applications developed with it.
Maximum Number of Recognizable MicroPeckerX Units
Applications developed with this product can recognize up to 4 MicroPeckerX units.
You cannot specify which MicroPeckerX units are recognized.
Reserved Areas in Structures
This product uses 4-byte alignment. Therefore, some structures include reserved members for alignment adjustment.
If you write to such a structure, the values in reserved areas are not used. If you read from such a structure, the values in reserved areas are undefined.
Log Information Acquisition
Send/receive log information is stored in a StMPXLog structure (log information) buffer allocated inside the DLL.
The structure buffer size is 1 MB per CH.
Log information can be acquired with the following APIs.
| API | Function | Notes |
|---|---|---|
| MPXGetLog | Acquires log information (send/receive data) during monitoring from the StMPXLog structure (log information) buffer allocated inside the DLL. | The caller does not need to prepare a structure array for storing the acquired log information. |
| MPXCANGetLogEx | Acquires log information (send/receive data) during monitoring into a caller-prepared array of StMPXCANLog structures (CAN log information). | The caller must prepare a structure array for storing the acquired log information. |
| MPXLINGetLogEx | Acquires log information (send/receive data) during monitoring into a caller-prepared array of StMPXLINLog structures (LIN log information). | The caller must prepare a structure array for storing the acquired log information. |
If there is no area available for storing log information in the buffer, a buffer overrun occurs and log information that could not be stored is lost. Periodically call APIs such as MPXGetLog before a buffer overrun occurs to acquire log information.
However, if there is no need to acquire or analyze log information, such as when the operation mode is set to simulation mode and only transmission is performed, a buffer overrun does not affect transmission processing.
Setting Parameters in StMPXCANSlot Structure (Slot Information)
The meanings of SendDelay (delay time for event transmission), SendOffset (transmit offset), SendCycle (transmit cycle), and MinTransInterval (minimum guaranteed transmission interval) in the StMPXCANSlot structure (slot information) are as follows.
| Member Name | Effect | Related Operation Mode |
|---|---|---|
| SendDelay | After the trigger condition set by MPXSetLogReplayTrigger or MPXChangeSlot is satisfied, the first frame is transmitted after the time specified by SendDelay has elapsed. | Simulation mode |
| SendOffset | After monitoring starts, the first frame is transmitted after the time specified by SendOffset has elapsed. | Simulation mode |
| SendCycle | After the time specified by SendCycle has elapsed since the previous frame transmission, the next frame is transmitted. | Simulation mode |
| MinTransInterval | The next frame is not transmitted until the time specified by MinTransInterval has elapsed since the previous frame transmission. | Simulation mode |